Use AS310e to control a damper
AS310e's analog output signal can be used to control the position of a fresh air damper to control co2 level.
It's easy to mount the actuator on the damper. Just drill four holes and bolt it on. The mounting plate and drive shaft are included with the damper. The actuator stabilizer is included with the actuator. You'll have to supply your own bolts and drill four holes. Two bolts attach the actuator mounting plate to the damper and two bolts hold the stabilizer bar in place.
A 24Vac, 20VA, control transformer supplies the power for both AS310e and the the damper actuator. 120Vac power feeds into the switch box and connects to the transformer primary. 24Vac output is carried by a two-wire cable from the transformer box to the location of the damper.
Attach the two-wire power cable to the actuator. From the actuator, run a four-wire cable to AS310e. Two wires supply 24Vac to operate AS310e, and two wires carry the analog output from AS310e back to the actuator.
Questions? You can contact us usng English language: email. You can contact us using Russian language: email. You can order from our online catalog. Mushroom Climate accepts payment by VISA and MasterCard and we won't charge your credit card until your order ships. You can also pay with Western Union Money Transfer, ask for details by email. Shipping by USPS Priority mail, USPS Parcel Post Air Mail, or USPS Global Express Mail (EMS).
|
Return to Mushroom Climate's Site Index AS310e Standard Factory Model AS310e High Humidity Model How to use AS310e with a relay for co2 control DIY relay co2 controller for 1/3 hp fan, using off-the-shelf parts. How to Adjust AS310e's Analog Output Signal How to use AS310e to control a damper AS310e controls fan speed with PWM power supply
Online catalog |